Three major considerations when installing and using reducer

1. It is strictly prohibited to use the direct hammering method when installing the output shaft of the hammer reducer, couplings such as couplings, pulleys, sprocket, etc. Because the output shaft structure of the reducer cannot withstand axial hammering, the available shafts The end screw is screwed into the coupling.

2, must install the vent cap (exhaust screw plug)
Before use, the plug at the highest position should be replaced with an exhaust screw plug to ensure that the reducer runs out of gas during operation. If it is not replaced in time, the reducer will run for a long time, which will cause the gas in the reducer to swell and the oil leak in the reducer.

3, timely replacement of lubricating oil, pay special attention to the first time.
Should pay special attention to the first oil change, reducer in the first run 300 to 400 hours should be replaced immediately after the replacement of lubricating oil every 1500 to 2000 hours. In addition, in the harsh working environment, high temperature and dusty working conditions, the lubricant should be inspected once every two weeks. It is found that there is dirt in the lubricant and the lubricant is replaced to keep the lubricant clean and extend the use of the reducer. Life, improve economic efficiency.

Changing the lubricating oil means purging the previous lubricating oil, flushing it, and then adding new lubricating oil again.